PL-243409
Reviews
Not reviewed yet
Producer
Content languages
English , Spanish
Certification labels
UL , CE
Warranty
60
Producer product code
AEL-PHVG
Solar PV

The Photovoltaic Application with Connection to Grid, “AEL-PHVG”, has been designed by EDIBON to study the energy production by photovoltaic panels and how this energy is injected to the grid.

In order to learn about solar energy production, the AEL-PHVG includes a programmable power supply which emulates an array of photovoltaic panels connected to the three-phase grid inverter. The grid inverter can be programmed by the user to create different conditions in the management of the energy of the photovoltaic panels. Besides, this inverter allows realize a dynamic power control with energy injected into the grid and, for this reason, this application is compatible with any EDIBON´s Smart Grid application. On the other hand, it is recommended to acquire the real photovoltaic panel and mobile halogen lamps panel in order to study the photovoltaic panel characteristics. The mobile lamps panel includes a current regulator to simulate solar radiance variations. It is recommended to acquire the variable resistor module and the multimeters to realize load test in the photovoltaic panel.

This application can work together other power generation sources to study the energy mix, their advantages and problems developed when alternate sources are interconnected into a power system.

This application can be combined with other applications of generation, transmission/distribution and load systems areas.

 

 

• N-ALI01. Industrial Main Power Supply.
Supply voltage: 400 VAC, 3PH+N+G.
ON-OFF removable key.
Output voltage connections:
Three-Phase + Neutral: 400 VAC.
Single-Phase: 230 VAC.
Three-Phase supply hose with IP44 3PN+E 32A 400 V connecting plug.
Differential magnetothermal, 4 poles, 25 A, 30 mA AC 6 KA.
Emergency stop push button.
GND terminal.
• N-EALD/A. Advanced Network Analyzer Module.
The network analyzer module allows fulfilling measurements, displaying and analyzing all the
parameters of the AC electrical networks. It has an LCD screen and push-buttons for the navigation
through the different menus. It includes specific software for monitoring current and voltage curves,
harmonics display, tariffs programming, alarms programming and electrical parameters storage.
Features:
Multifunctional three-phase power meter:
Single and three-phase voltage. Up to 690 VAC L-L.
Phase and line current. Current range up to 200%. Measurement from 0-10 A.
Active, reactive and apparent power.
Suitable frequencies: 25 Hz, 50 Hz, 60 Hz y 400 Hz.
Display of the V-I vector diagram.
Supply voltage: 85-265 VAC.
Energy quality control:
Current and voltage individual harmonics measurement. Up to the 40th harmonic.
THD voltage and current, TDD and K-factor.
Maximums and minimums display.
Waveforms display, 128 samples/sec.
Events and data storage.
Harmonics analyzer:
THD voltage and current, TDD current and K-factor, up to the 40th harmonic.
Current and voltage harmonic spectrum and angles.
Tariff programming:
Class 0.5S IEC 62053-22, active and reactive power in four quadrants.
Measurement of the total and per phase three-phase active, reactive and apparent powers.
Usage time, 4 energy/demand records of total tariffs.
8 tariffs, 4 seasons, 4 types of days.
Automatic daily report of energy consumption maximums and minimums.
Communications:
Modbus TCP communication protocol with Ethernet interface.
• PSPS/A. Advanced Panel Simulator Power Supply.
This power source allows carry out the programming of characteristics curves of photovoltaic panels.
Open-circuit voltage: 500 V.
Closed-circuit current: 10 A.
Power output: 1500 W.
• N-PSM. Power Switch Module.
Supply voltage: single-phase 230 VAC.
Power terminals:
Four power input terminals (3PH+N).
Four power output terminals (3PH+N).
Auxiliary contacts:
One “NO” contact.
One “NC” contact.
Two push-buttons to open / close the power terminals and auxiliary contacts.
Two control contacts of 24 VDC.
Two voltage supply outputs of 24 VDC.
• N-INV02. Three-Phase Grid Inverter Module 2.
DC circuit breaker.
Overload voltage protection for photovoltaic and bus terminals.
DC input voltage range: 0-500 VDC.
Output voltage: 3x 400 V/ 50/60 Hz.
Power output: 3000 W.• N-REVT/1K. 1kW Three-Phase Variable Resistors Module.
Three banks with three-phase variable resistances of 150-500 Ohms.
Supply voltage: 230 VAC+N+GND.
Fuses: 3 x 2 A.
• N-INDT/3C. 3 x 300 VAr Three-Phase Configurable Capacitors Module.
Configurable Star and Delta connection.
Three benches with three-phase inductances of 5 H each one.
Supply voltage: 230 VAC + N + GND.
Nominal voltage: 400 VAC.
Nominal power: 3 x (3 x 100) VAr.
• N-REV01. Single-Phase Variable Resistor Module 0-1 kOhm.
0-1 kOhm variable resistor.
Maximum Power: 500 W.
Potentiometer.
Terminals:
Three terminals for taking the maximum resistance or a variable value.
• MED65. Digital Multimeter (2 Units).
Digital multimeter of about 3 ½ digits, with double-jack ending cables of about 4 mm to facilitate
interconnections.
With this digital multimeter we will be able to measure:
Voltage.
Current.
Resistance.
Capacitors capacity.
Temperature.
• N-ZIS. Zero Injection Smart Meter Module.
Nominal voltage: 400 VAC.
Máx. Current: 3x50 kA.
Self-consumption: 2,5 W.
Starting Current: 40 mA.
Accuracy class: 1.
Active energy accuracy: Class B (UNE- EN50470).
Reactive energy accuracy: Class 2 (EN/IEC 62053-23).
8 Digits LCD display.
IP51 (front frame) and IP52 (terminals) protections.
Modbus RTU communication.
• N-REL09. Time Electronic Relay Against Overcurrents (1.2 - 7 A).
Electronic thermal relay.
Overload protection.
Range 1.2 - 7 A.
Reset and test function.
1 NONC contact.
Temporization.
• LP3. 3 lamps Panel.
Power: 3 x 250 W.
Switch ON/OFF.
Intensity Regulator.
Aluminium frame.
• FVP96. 96W Photovoltaic Panel.
Maximum Power: 96W.
Voltage at maximum power: 17,8 V.
Current at maximum power: 3,7 A.
Short-Circuit Current: 4,05 A.
Opened-Circuit Voltage: 22,25 V.
• All necessary cables to realize the practical exercises are included.
Cables and accessories, for normal operation.
Manuals: This unit is supplied with the following manuals: Required Services, Assembly and Installation, Starting-up, Safety, Maintenance
& Practices Manuals.AEL-PHVG/ICAI. Interactive Computer Aided Instruction Software System:
This complete software package consists of an Instructor Software (EDIBON Classroom Manager - ECM-SOF) totally integrated with the Student Software (EDIBON Student Labsoft - ESL-SOF). Both are interconnected so that the teacher knows at any moment what is the theoretical and practical knowledge of the students.
- ECM-SOF. EDIBON Classroom Manager (Instructor Software).
ECM-SOF is the application that allows the Instructor to register students, manage and assign tasks for workgroups, create own content to carry out Practical Exercises, choose one of the evaluation methods to check the Student knowledge and monitor the progression related to the planned tasks for individual students, workgroups, units, etc... so the teacher can know in real time the level of understanding of any student in the classroom.
Innovative features:
• User Data Base Management.
• Administration and assignment of Workgroup, Task and Training sessions.
• Creation and Integration of Practical Exercises and Multimedia Resources.
• Custom Design of Evaluation Methods.
• Creation and assignment of Formulas & Equations.
• Equation System Solver Engine.
• Updatable Contents.
• Report generation, User Progression Monitoring and Statistics.

- ESL-SOF. EDIBON Student Labsoft (Student Software).
ESL-SOF is the application addressed to the Students that helps them to understand theoretical concepts by means of practical exercises and to prove their knowledge and progression by performing tests and calculations in addition to Multimedia Resources. Default planned tasks and an Open workgroup are provided by EDIBON to allow the students start working from the first session. Reports and statistics are available to know their progression at any time, as well as explanations for every exercise to reinforce the theoretically acquired  technical knowledge.
Innovative features:
• Student Log-In & Self-Registration.
• Existing Tasks checking & Monitoring.
• Default contents & scheduled tasks available to be used from the first session.
• Practical Exercises accomplishment by following the Manual provided by EDIBON.
• Evaluation Methods to prove your knowledge and progression.
• Test self-correction.
• Calculations computing and plotting.
• Equation System Solver Engine.
• User Monitoring Learning & Printable Reports.
• Multimedia-Supported auxiliary resources.

 

 

Voltage availability
100-127V, 220-240V
Production lead time
105 days
Teacher materials available
Yes
Student materials available
Yes
E-Learning modules
No

Similar products

Best products in this category
The Stand-Alone Photovoltaic Application, “AEL-SAPV”, has been designed by EDIBON to study the energ
Solar PV
Content languages
English , Spanish
Add to quotation list
STAND ALONE AND NETWORK CONNECTED The equipment EN 01.5 reproduces a scale, complete photovoltaic
Solar PV
Content languages
Spanish , English
Add to quotation list
The Computer Controlled Photovoltaic Solar Energy Unit, "EESFC", includes equipment that uses the ph
Solar PV
Content languages
English , Spanish
Add to quotation list
Modular trainer for the theoretical and practical study of the electric energy generation from photo
Solar PV
Content languages
English , Italian , Spanish , French
Add to quotation list